(514) 336-3820 | sales@airtekltd.com | Dealers login here

Fire Sprinkler Systems · Canadian Manufacturer Since 1975

The CompressorBehind Every Protected Building

Airtek manufactures single-stage electric air compressors purpose-built for dry-pipe and pre-action fire sprinkler systems. ASME-coded tanks, 30–45 PSI operating range, 0.5 to 5 HP, tank or base mounted. Designed and assembled in Canada.

  • Fire Sprinkler Rated

  • ASME & CRN Approved Tanks

  • Designed & Assembled in Canada

  • Ready in 2–4 Business Days

Why Airtek

Built for Fire Protection. Nothing Else.

Fire sprinkler contractors need more than a repurposed industrial compressor. Airtek builds units specifically for the pressure range, fill time, and reliability standards that dry-pipe and pre-action systems demand.

ASME & CRN Coded Tanks

Select models carry ASME & CRN coding — the tank certification inspectors and AHJs look for on fire system equipment.

40 PSI in Under 30 Minutes

Our ASBT series is designed to fill sprinkler systems to 40 PSI within 30 minutes — meeting NFPA 13 air maintenance requirements.

Right Pressure Range — 30 to 45 PSI

Factory-set for the supervisory pressure range fire sprinkler systems actually operate in. No field adjustment needed.

Duplex Option for Critical Applications

The ASBT7-DUP provides full redundancy — two pumps, one skid — for hospitals, data centers, and high-consequence facilities.

Dealer Network Across Canada

Orders ship through local dealers who know the equipment. French and English support for contractors across Quebec and beyond.

Full Spec Comparison

All variants across both series. Click a SKU to order direct.

SKU Series HP Type CFM Displacement Max PSI Pressure Range
ASB2 Base Mounted0.5 HPSingle Stage3.69 CFM30–45 PSI
ASB3 Base Mounted0.75 HPSingle Stage5.14 CFM30–45 PSI
ASB4 Base Mounted1 HPSingle Stage8.38 CFM30–45 PSI
ASB5 Base Mounted1.5 HPSingle Stage10.01 CFM30–45 PSI
ASB6 Base Mounted2 HPSingle Stage15.02 CFM30–45 PSI
ASB7 Base Mounted3 HPSingle Stage25.08 CFM30–45 PSI
ASB8 Base Mounted5 HPSingle Stage37.5 CFM30–45 PSI
ASB9 Base Mounted7.5 HPSingle Stage30–45 PSI
ASBT2 Tank Mounted0.5 HPSingle Stage2.1 CFM100 PSI30–45 PSI
ASBT3 Tank Mounted0.75 HPSingle Stage3.4 CFM100 PSI30–45 PSI
ASBT4 Tank Mounted1 HPSingle Stage4.5 CFM100 PSI30–45 PSI
ASBT5 Tank Mounted1.5 HPSingle Stage5.2 CFM100 PSI30–45 PSI
ASBT6 Tank Mounted2 HPSingle Stage9.9 CFM100 PSI30–45 PSI
ASBT7 Tank Mounted3 HPSingle Stage18.1 CFM100 PSI30–45 PSI
ASBT7-DUP Tank Mounted3 HPDuplex105–140 PSI
ASBT8 Tank Mounted5 HPSingle Stage25.2 CFM100 PSI30–45 PSI

Full dimensional specs and wiring diagrams in the Spec Sheet PDF →

Built for the Contractors Who Install

If you install, design, or maintain fire sprinkler systems — our compressors are engineered for your work.

Commercial Buildings
Office towers, retail, multi-unit residential requiring dry-pipe or pre-action systems.
Warehouses & Logistics
Large-footprint facilities where high-capacity compressors (3–7.5 HP) are required.
Hospitals & Healthcare
Critical applications where duplex configuration (ASBT7-DUP) ensures zero downtime.
Data Centers
Pre-action systems protecting sensitive environments — duplex redundancy available.
Industrial Facilities
Manufacturing plants and process facilities requiring high-CFM fire suppression pressurization.